J1V3 Assessment

We are accredited energy assessors committed to providing accurate JV3 Assessment reports.

Passive Energy 0011 J1v3 1

What is a J1V3 Assessment?

A JV3 assessment, also known as a Verification Using a Reference Building (VURB), is part of the National Construction Code Volume 1. It can be nominated as an alternative pathway to demonstrate compliance with Part JP1 Energy use.

Why is a J1V3 Assessment important?

A J1V3 Assessment is not a mandatory requirement when meeting Section J compliance. However, it can be an alternative solution to meeting Section J1: Building Fabric compliance.

The J1V3 assessment pathway can be nominated to the following building classes:

  • Class 2 - Common areas to class 2 building.
  • Class 3 - Residential building other than class 1 and class 2
  • Class 5 - An office building
  • Class 6 - Shops
  • Class 7 - Car parking and storage
  • Class 8 - Laboratory and factory
  • Class 9 - Health care, assembly building in school, an aged care facility
Passive Energy 0010 J1v3 2
J1v3 1

Why would we consider nominating a J1V3 Assessment over a standard Section J?

A J1V3 Assessment may be more effective than a standard Section J when your building’s complex design does not meet the Deemed to Satisfy (DtS) requirements under the National Construction Code (NCC).

J1V3 allows more flexibility concerning design choices, as you can create as you see fit as long as it does not exceed the reference building's energy usage targets.

J1V3 is much like a non-residential equivalent of NatHERS modelling, allowing flexibility to choose glazing and building elements as long as it stays within the annual energy consumption of the Deemed-to-Satisfy (DtS) building.

How to achieve compliance with the National Construction Code (NCC)

The NCC allows multiple options to be nominated to achieve compliance.

1. Using the Deemed-to-Satisfy Provisions found within Part J4-J9

This is the standard Section J report and is mandatory, forming the base for the additional options. Facade and lighting calculators are included with reports demonstrating how the commercial space will meet compliance.

In many instances, the specifications listed are suitable for the project and no further reports will be required.

2. The Verification using a reference building (J1V3)

This method involves building 3D models in commercial energy efficiency programs like Design Builder and IES VE.

The results from the Section J report are modelled into what we call the ‘reference’ model. Then a secondary model is prepared, labelled as the ‘proposed' model.

The commercial energy modelling software allows us to improve the glazing and insulation specifications, as everything is included in the model and simulated together.

Key Components of a J1V3 Assessment

The NCC allows multiple options to be nominated to achieve compliance.

J4 Building Fabric

One of the key aspects covered in a Section J report is the thermal performance of the building envelope. This includes insulation levels for walls, roofs, and floors. The report outlines the required R-values (thermal resistance) to ensure that the building maintains an optimal internal temperature while minimising the need for excessive heating or cooling.

Windows and glazed areas are vital in a building's energy performance. The Section J reports specify the maximum allowable U-values for windows, which measure the rate of heat transfer. Implementing energy-efficient glazing solutions can greatly contribute to reducing heat loss or gain, resulting in a comfortable interior.

J6 Air conditioning, Heating and Ventilation

Heating, ventilation, and air conditioning (HVAC) systems are significant contributors to a building's energy consumption. The detailed specifications are not included in the Section J report, as this must be completed by a service or mechanical engineer.

The details of the efficiency requirements for these systems are nominated, promoting the use of high-efficiency equipment and controls. Properly designed HVAC systems ensure effective climate control while minimising energy wastage.

J7 Lighting

This focuses on lighting efficiency. Lighting is vital in building functionality and occupant comfort, but inefficient lighting systems can contribute to unnecessary energy consumption.

Section J6 outlines requirements to ensure your lighting designs are aesthetically pleasing and energy-efficient. This section covers lighting power density limits, control systems, and usage of energy-efficient lighting technologies.

What are the accredited requirements to prepare a compliant J1V3 Assessment?

There are no accreditation requirements to prepare a compliant JV3 assessment. However, you will need a good working knowledge of the NCC and understand how the NCC calculators work. Proficiency in commercial energy modelling software is also necessary.

This is why it is best to leave the process of completing a JV3 Assessment report to professional energy assessors. We know how to meet compliance and use the energy modelling software accurately to get the best results for your project.

J1v3 2webp

Our process for completing a J1V3 assessment (VURB)

There are two software we are well versed in at PassivEnergy: Design Builder and Speckle.

Architectural plans are then uploaded into our chosen software, after which we model the commercial buildings as 3D geometrical objects, similar to how you would model using 3D programs like Revit and ArchiCAD.

The model includes all the building elements such as:

  • Walls
  • Glazing elements
  • Doors
  • Floors
  • Ceiling and roof system
  • Heating, ventilation and air conditioning (HVAC) details

Two models are created, a reference model and a proposed model.

The reference model includes the specifications listed within Section J4 compliance, while the proposed model includes the improved specifications.

The proposed build must have a thermal comfort level between a Predicted Mean Vote of -1 to +1 of:

  • not less than 95% of the floor area of all occupied zones and
  • not less than 98% of the annual hours of operation

The building models need to comply with the following requirements:

  • The requirements found in JVa
  • The requirements found in JVb
  • ANSI/ASHRAE Standard 140

Once we’ve completed the process, you will get:

  • A fully compliant Section J report includes J4 to J9
  • NCC Facade calculator
  • J1V3 modelling (A reference and proposed model)
  • J1V3 simulations and computations
  • Insulation values for floor, walls and ceiling
  • Glazing Values (U-Value & SHGC-Values)
    • Generic values per JV3 assessment
  • NCC J7 Lighting calculator
  • Requirements for J5 building sealing
  • Requirements for J6 HVAC systems

What we need from you to prepare a J1V3 Assessment

To prepare a JV3 assessment that will be certified for your building permit, we will need a set of construction drawings with the following information:

  • Site plan with neighbouring information
  • Floor plan
  • Elevations with cladding details and window opening style
  • Section with floor construction type
  • Window schedule
J1v3 3
Google Reviews
Google
Jackson T profile picture
Jackson T
May 25, 2023
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Best energy assessor's I've ever worked with. These guys have great communication, fast turn arounds and are always super helpful when requesting feedback on a design proposal.
Google
Nor Eltaha profile picture
Nor Eltaha
May 24, 2023
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Rob from PassivEnergy managed to achieve a 7 star energy rating for my home by offering some design tips. Communication and service was excellent. Highly recommended.
Google
Nikolaos Tzovaras profile picture
Nikolaos Tzovaras
May 23, 2023
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
PassivEnergy has been my go-to thermal performance assessing company, and their service has been consistently exceptional. Their expert team's deep knowledge and commitment to staying ahead of advancements in the field have significantly influenced the success of my building designs. Their personalised approach, professionalism, and timely delivery have made them an invaluable partner. I highly recommend PassivEnergy for their outstanding service and dedication to sustainable outcomes.
Google
Roman Z profile picture
Roman Z
October 3, 2022
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I have used the team at PassivEnergy for a few of my townhouse developments over the last couple of years. Their knowledge on the preferred preference of the individual councils I have developed in has been impressive and the tips they provided in the design layout meant I was able to save on window glazing. Thanks team, see you on the next development.
Google
Stacey Pierce profile picture
Stacey Pierce
July 1, 2022
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Thank you Rob for your fantastic advise and knowledge. Your communication, customer service and turn around time exceed our expectations by far. We highly recommend Rob at PassivEnergy. Thank you very much.
Google
Michael Woolfe profile picture
Michael Woolfe
December 22, 2020
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I recently dealt with Rob from Passive energy to seek some assistance with existing north facing windows adjacent to a proposed garage. Rob’s vast knowledge of the current building regulations and energy requirements made ease of understanding a tricky situation. Rob’s professionalism and efficient turnaround time to provide a solution enabled the project to keep moving forward. I would highly recommend PASSIVENERGY services for all energy performance requirements for proposed & existing dwellings. A+ service
Google
Jane RD profile picture
Jane RD
May 26, 2020
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
We have been dealing with Rob and PassivEnergy for a number of years now and couldn’t speak more highly of them. They have great service and turnaround times and we’ve never had a problem while working with PassivEnergy on our projects. They are always helpful with any questions or revisions and offer solutions for those tricky situations. Rob and the team are our first port of call for energy assessments or WSUD reports. We look forward to working with the team for a long time to come. - On behalf of the team at Lateral Building Design.
Google
Kristie Nevill profile picture
Kristie Nevill
December 7, 2017
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I found PassivEnergy via a Google search knowing nothing other than that I required an energy report for my building permit application. Rob was quick at getting back to me with a quote and very reasonably priced in comparison to his competitors. The report was detailed and he worked closely with us to answer all the questions we had. The report was delivered in the promised timeframe and the customer service was exceptional. I cannot recommend Rob and PassivEnergy more highly!

Our fast & efficient process

Getting a 6 Star Energy Rating does not need to be timely, confusing or expensive.

Infinity. Passive Energywebp

See our work

Contact us and we will handle all the Section J compliance requirements for you and provide an accurate JV3 Assessment report for your project.

Get a quote

Name(Required)
Drop files here or
Accepted file types: jpg, pdf, ai, png, doc, docx, xls, xlsx, Max. file size: 40 MB, Max. files: 4.

    FAQs

    What are glazing and insulation value results?

    The JV3 assessment produces glazing values and insulation R-Values, which demonstrate how the building fabric performs. 

    Insulation is measured as an R-Value. A high R-Value is better for an energy rating, until a certain point.

    Glazing is measured by:

    • U-Value measures the glazing or frame's ability to slow down the ambient temperature from outside to inside and vice versa. The lower the U-Value, the better the rating.
    • SHGC-Value measures solar rays, directly from the sun. Warm climates benefit from a lower SGHC as it blocks the sun while cold climates benefit from a higher SHGC to welcome the sun in.
    How do I make sure I don’t blow out my budget with glazing results?

    It is not uncommon to prepare a Section J report with the glazing results blowing out the budget dramatically. Having to provide a client with a report that specifies high-performance commercial double glazing is not ideal, and the NCC facade calculator does have limiting input parameters that we can adjust to improve the results. 

    Because the project documentation is so advanced, usually at the building permit stage, reducing the glazing area to improve the results is not an option. This is where we recommend preparing a JV3 assessment. Preparing 3D models in commercial energy analysis software allows us to run simulations to produce more accurate and favourable results. The results from the JV3 assessment override Section J1 - Building fabric results.

    When is the best time to do a JV3 assessment?

    As soon as the design is complete, send us the plans so we can do preliminary insulation and facade calculations. This will give you the knowledge that the commercial building project performs well. If it does not, it allows you to make improvements early on.

    How do we prepare a JV3 assessment for extensions for building projects?

    Extension to existing commercial space will require full Section J calculations, however, the building owner can request partial compliance for the existing external walls, which can be allowed to remain unmodified. 

    The existing roof will likely need to be upgraded as there is usually access to the ceiling space. These requirements to upgrade the existing building fabric are always up to the discretion of the building surveyor. The JV3 assessment pathway could be beneficial here to ensure the proposed specifications are within the construction budget.

    How do we prepare a JV3 assessment for alterations only for building projects?

    It is unlikely that there would be any benefit of nominating a JV3 assessment for alterations only as if the proposed building works are internal alterations only, then we only need to prepare a Section J6 Lighting report. This report will ensure the new lighting design is compliant with the building classification that is proposed.

    If the proposed building alterations include a new conditioned area, such as an office, that was previously an unconditioned space, then it is likely that the new internal walls enclosing the conditioned space will require insulation calculations and the J6 Lighting calculations. These insulation values can be derived from Section J Building Fabric with fairly standard results.